Throughput vs Manual
In-house benchmark
70%
Sample Prep Time Saved
In-house benchmark
1hr
No-code Initial Setup
NOTABLE basis
Local
Dedicated Korea-based Tech Support
On-site visits
Windy Workflow Preview

Build Your Workflow
in 4 No-code Steps

Walk through real application scenarios step by step. Preparation, design, run, and results flow seamlessly through Windy's no-code interface.

STEP 01 · PREPARATION

Prepare Samples and Reagents

Prepare samples, reagents, and consumables for NGS library prep. NOTABLE's dual head (Left 1-channel + Right 8-channel) handles bulk reagents and index adapters in a single instrument.

  • 96-well PCR plate, magnetic beads, adapter reagents
  • 200µL tip box, reagent trough, magnetic separation module
  • Sample input plate, output library plate
NGS Library Prep — PREPARATION screen
STEP 02 · DESIGN

Design Protocols via No-code Wizard

Follow Windy's step-by-step wizard to design the NGS library prep protocol visually. The workflow comes together with clicks alone, no code required.

  • Select fragmentation, end repair, and adapter ligation steps
  • Set dispense volume, mixing cycles, and incubation time
  • Use validated reagent kit compatible protocol templates
NGS Library Prep — DESIGN screen
STEP 03 · RUN

Automatic Run and Real-time Monitoring

NOTABLE runs the designed protocol automatically. The 8-channel head dispenses Master Mix and reagents row by row in bulk, while the 1-channel head precisely dispenses a unique index adapter for each sample. Protocol Runner offers progress, elapsed time, and pause controls, and transitions to the Run Report page on completion.

  • 8-channel row-wise bulk dispensing + 1-channel index precision dispensing
  • Step-by-step progress, remaining time, and alerts
  • Pause, resume, and step jump available
NGS Library Prep — RUN screen
STEP 04 · RESULT

Library Completion and Data Organization

Automatically processed libraries are ready up to the step before sequencing. Run logs and per-step metadata are saved automatically for future reproduction and verification. Run Report shows the results of every step, elapsed time, and labware used at a glance.

  • 96-well library batch completion (8-channel sequential processing)
  • Automatic run log save (for reproducibility)
  • Export result data in sequencer-ready format
Book a Demo
NGS Library Prep — RESULT screen
STEP 01 · PREPARATION

Master Mix and Sample Preparation

Prepare the master mix, primers, and samples needed for qPCR dispensing. NOTABLE's dual head (Left 1-channel + Right 8-channel, both 200µL) dispenses even small volumes with precision.

  • qPCR master mix, primer / probe sets
  • 96-well or 384-well PCR plate
  • Prepare samples at standardized concentration after quantitation
qPCR Plate Setup — PREPARATION screen
STEP 02 · DESIGN

Visual Plate Layout Design

Visually arrange samples, standard curves, and negative / positive controls on a 96-well or 384-well plate. Complete complex plate maps instantly with drag and drop.

  • Color-coded positions for samples, controls, and standard curves
  • Auto-placement of replicate triplicates and duplicates
  • Auto-optimization of dispense volume and order
qPCR Plate Setup — DESIGN screen
STEP 03 · RUN

Automatic Precision Dispensing

NOTABLE dispenses precisely according to the designed plate layout. The 8-channel head dispenses Master Mix and Primer row by row in bulk, while the 1-channel head precisely dispenses NTC, PC, and Standard to secure qPCR result reliability. Protocol Runner offers progress, elapsed time, and pause controls, and transitions to the Run Report page on completion.

  • CV below 4% at 1µL dispensing (in-house measurement)
  • Auto-dispensing in order of master mix, primers, samples
  • Automatic tip change management to prevent cross-contamination
qPCR Plate Setup — RUN screen
STEP 04 · RESULT

qPCR Analysis Ready

The dispensed plate is ready to go straight into the qPCR instrument. Dispensing logs and plate maps are saved automatically and remain available during result interpretation. Run Report shows the results of every step, elapsed time, and labware used at a glance.

  • 96 or 384-well simultaneous dispensing complete
  • Plate map, dispense volume, and run time logged automatically
  • Result data connected to qPCR instrument software
Book a Demo
qPCR Plate Setup — RESULT screen
Adoption Process

Your Automation Journey · Simpler Than You Think

ABLE Labs supports you from consultation through installation and beyond.

STEP 1

Expert Consultation

Share your lab environment and goals; we propose the optimal setup.

STEP 2

On-site PoC

Test in your own lab before purchase. Verify performance firsthand.

STEP 3

Installation and Onboarding

Dedicated engineer installation. First protocol running within about an hour.

STEP 4

Ongoing Support

Korea-based responsive support. On-site, remote, and Korean documentation available.

Explore. Freely.

Talk with an ABLE Labs specialist in a 30-minute consultation and find the automation setup that fits your lab.

Expert Consultation · On-site Demo · On-site PoC

Back to top