Home Products NOTABLE96
High-Throughput Flagship

NOTABLE96

96 wells. One stroke. Zero waiting.

Maximize throughput with 96-channel simultaneous pipetting.
96 channels at once — over 5,500 wells/hour (96ch × 3 plates/run).
The solution for pharma R&D and HTS.

96ch Simultaneous 96ch Simultaneous Dispense 5–200 µL CV < 5% @ 2µL · 50Tip
NOTABLE96 — Front View
NOTABLE96 — Angled Front View
NOTABLE96 — Side View
NOTABLE96 — Top Diagonal View
NOTABLE96 in Motion

96-channel parallel
automation in action

New benchmark for high-throughput screening

96ch
Simultaneous channels
5,500+
Max wells/hour
5–200µL
Dispensing volume range
12 Slots
Configurable deck positions
Key Differentiators

Why NOTABLE96

96-Channel Simultaneous Processing

Equivalent throughput to large global instruments at a competitive price. 96 channels dispense all 3 plates simultaneously in a single run.

3 plates
96ch simultaneous (3 plates / run)

Same ABLE Labs UX

Identical software platform as NOTABLE. Existing NOTABLE users can switch instantly with no additional training.

NOTABLE → NOTABLE96 instant transition

24h Local Technical Support

Not weeks-long after-sales service from global vendors — 24-hour direct on-site support from a dedicated Korea-based team.

On-site visits by local engineers

Verified Precision

CV < 5% at minimum volume (2µL, 50Tip), with %CV ±0.46 at 200µL (200Tip) — measured in-house across multiple runs. Meets the reproducibility requirements for drug screening and genomics analysis.

CV < 5%
@ 2µL · 50Tip (minimum volume)
%CV ≤0.46
200µL, 200 Tips (measured)
%D ≤0.35
Accuracy (200Tip, 200µL)
96ch
Simultaneous channels
NOTABLE96 — Deck Slot Layout
Specifications

NOTABLE96 Specs

Channels 96-channel simultaneous
Volume (Single) 5 – 200 µL
Volume (Multi) 10 – 100 µL (200Tip) / 5 – 20 µL (50Tip)
Precision (marketing) CV < 5% @ 2µL (50Tip, minimum volume)
Precision 200µL %D ±0.35, %CV ±0.46 (200Tip)
Precision 50µL %D ±0.44, %CV ±0.76 (50Tip, 50µL)
Throughput 96ch simultaneous dispense (3 plates / run)
Deck Slots 12
Dimensions W 640 × D 580 × H 660 mm
Weight 50 kg
Power 221W max
Software Cloud-based, drag-and-drop UI
Pricing Contact us for pricing
Applications

What Research
Is It Built For?

NOTABLE96 is optimized for pharma R&D and high-throughput screening facilities where large-volume processing is critical.

HTS (High-Throughput Screening)
Simultaneous screening of large-scale drug candidate libraries
Drug Candidate Screening
Automated processing of thousands of compound libraries
Genomics Sample Preparation
NGS library prep, DNA/RNA dispensing
High-Throughput ELISA
Simultaneous all-channel processing in 96-well format
All 96-well Based Experiments
Drug discovery, compound screening, and more
Lab automation — deck slots and robot arm
NOTABLE vs NOTABLE96 — Selection Guide
NOTABLE
  • · Academic labs
  • · Small/mid biotech
  • · 1ch & 8ch
  • · Flexible workflows
NOTABLE96
  • · Large pharma R&D
  • · HTS facilities
  • · 96ch simultaneous
  • · High-volume processing
FAQ

Frequently Asked Questions

Can I use it with no coding knowledge?
Yes. NOTABLE96 uses the same Windy software as NOTABLE — drag-and-drop interface, no programming required. Existing NOTABLE users can switch immediately with no additional training.
What is the precision of 96-channel simultaneous dispensing?
CV < 5% at minimum volume (2µL, 50Tip), measured in-house. At 200µL (200Tip), precision improves to %CV ±0.46. Detailed per-condition data is available in the spec table or on request.
What is the throughput speed?
With 96-channel simultaneous dispensing, NOTABLE96 achieves 5,500+ wells/hour (measured 5,548 wells/hour, 200Tip, 3 plates/run) — dramatically faster than 8-channel methods.
Is it suitable for high-throughput screening (HTS)?
Yes. NOTABLE96 is optimized for HTS workflows. 96-channel simultaneous dispensing, unattended continuous operation via Gripper & Stacker modules, and LIMS integration via REST API make it well-suited for large-scale compound screening.
Can it be used in GMP or regulated environments?
NOTABLE96 can be used in the non-clinical research phase of GMP manufacturing environments. IQ/OQ/PQ validation is supported, and qualification documentation can be provided on request.
Can it integrate with LIMS or ELN systems?
Integration with LIMS, ELN, and other external systems is supported via REST API. Integration guides for major platforms are in development; contact us for custom integration requirements.
Are the Gripper and Stacker modules sold separately?
The Gripper (automated plate transfer) and Stacker (auto-loading & supply) modules are optional add-ons. If you need a fully automated line, contact us for a bundled configuration quote.
Does it require proprietary consumables?
No. NOTABLE96 is compatible with standard SBS/ANSI/SLAS tips and microplates — no proprietary consumables needed. A recommended consumables list is available on request.
Is a Proof-of-Concept (PoC) trial available before purchase?
Yes. We offer an on-site PoC program so you can validate performance with your actual screening protocols in your own lab environment before committing to purchase.
How does after-sales service and maintenance work?
Dedicated Field Service Engineers (FSEs) respond within 24 hours and provide on-site service. Standard maintenance is included for one year after purchase, with ongoing support available through a service agreement.
Maximize Screening Speed

Maximize your
screening speed.

Free consultation and on-site PoC provided before purchase. Work with an ABLE Labs expert to find the right configuration for your lab.

Free consultation · On-site demo · PoC validation